Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
10047-9700-07
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
Πληροφορίες ανταλλακτικού
Electrostatic device
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Power Supply
Κωδικός ονόματος στοιχείου:
00740
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
10.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.590 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.439 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Pacer special
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
60000.0 feet
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
15.65 dc pounds per hour dry single operating power rqmt and 31.5 dc pounds per hour with retaining chain single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
15.0 dc volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-15.0 dc volts 6th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-5.15 dc volts 5th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
1.1 dc volts 4th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
12.5 dc volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.15 dc volts 3rd power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-54.0/+65.0 degrees celsius
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Over current protector and over voltage protector and over temperature protection
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.05 dc amperes 4th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.15 dc amperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.3 dc amperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
1.55 dc amperes 5th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
-0.3 dc amperes 6th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
8.0 dc amperes 3rd power output
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature:
Hardened
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiating by different repair parts, signature resistor r2