Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
30-103
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Motor-generator
Κωδικός ονόματος στοιχείου:
00830
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
11.600 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
15.800 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
13.900 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac input
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Totally enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bed plate
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Fan cooled
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
9.120 inches
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
7.880 inches
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
115.0 line to line low output or 200.0 line to line high output
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
220.0 line to neutral low input or 380.0 line to neutral high input
MRC:
The number of alternating current phases.FAAZ
Phase:
Three input
MRC:
The number of alternating current phases.FAAZ
Phase:
Three output
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0 output
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 input
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
12 wire lead