Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
3165195
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Electrical Solenoid
Κωδικός ονόματος στοιχείου:
00310
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2a mounting facility stud
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand mounting facility stud
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Base end actuator
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
0.719 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
1.156 centimeters
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.656 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Any acceptable
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
121.0 degrees celsius
MRC:
The measurement of the distance that the actuator protrudes from the body.AFGK
Actuator Length:
Between 0.474 inches and 0.494 inches
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately rugged
MRC:
The length of a straight line which passes through the center of the actuator,and terminates at the circumference.AFUR
Actuator Diameter:
Between 0.155 inches and 0.157 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of magnetic coils provided.APAF
Magnetic Coil Quantity:
1
MRC:
A measurement of the opposition to the flow of direct or alternating current.APCC
Electrical Resistance:
28.15 ohms
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Circumference
MRC:
The value of electrical energy for which the item is rated.ARQE
Electric Power Rating:
7.0 watts
MRC:
The voltage rating at which the item is designed to operate,expressed in volts.ASXH
Voltage Rating In Volts:
13.9 dc
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 threaded stud
MRC:
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
Storage Type:
General purpose warehouse
MRC:
Indicates the torque rating,and its type.BKPH
Torque Rating And Type:
0.06 inch-pounds starting and 0.10 inch-pounds end
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
Cubic Measure:
0.689 cubic inches
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
48 mounting facility stud
MRC:
The movement of the actuator when force is applied.CNXT
Actuator Stroke Type:
Rotary
MRC:
Indicates the type of means provided for connection of the power takeoff.CNXX
Power Takeoff Connection Type:
Plain
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.099 inches mounting facility stud
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Two position in-line
MRC:
The direction in which an item is designed to rotate,when viewed axially and the angular degree of travel from the de-energized to the energized position.CSQY
Rotation Direction And Energizing Stroke In Angular Deg:
45.0 counterclockwise
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc mounting facility stud
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead