Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
d4250
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Electric Heat Treating Furnace
Κωδικός ονόματος στοιχείου:
06243
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Floor
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
20.000 inches
MRC:
A measurement of the longest inside dimension of an item,in distinction from width.ADJU
Inside Length:
36.000 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
1250.0 degrees celsius
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
24.000 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+325.0/+1250.0 degrees celsius
MRC:
Indicates the design type of the item.APGF
Design Type:
Electrode salt bath
MRC:
Indicates the type of temperature control device provided.AZFX
Tempurature Control Device Type:
Automatic
MRC:
The rated power that an item can safely consume or provide,measured in kilowatts.CFSP
Wattage Rating In Kilowatts:
35.0
MRC:
An indication of whether or not a tilting hearth is included.CFSQ
Tilting Hearth:
Not included
MRC:
An indication of whether or not a work holding basket is included.CFSR
Work Holding Basket:
Not included
MRC:
Indicates the location and number of doors and/or openings.CFSS
Door/opening Location And Quantity:
1 opening in top
MRC:
An indication of whether or not a counterweight(s) is included.CFST
Counterweight:
Not included
MRC:
An indication of whether or not equipment for a flame curtain is included.CFSW
Equipment For Flame Curtain:
Not included
MRC:
The means used to operate the access.CGSP
Access Operation Method:
Manually operated cover
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three