Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
mil-h-11049
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Portable Duct Type Heater
Κωδικός ονόματος στοιχείου:
13028
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Wheel
MRC:
Indicates the heat medium type for which the unit is designed.ABAM
Heat Medium Type:
Air
MRC:
The position of the outlet(s) on the item.ABAQ
Outlet Position:
In the same direction
MRC:
The number of heat outlets included on the item.ABAW
Heat Outlet Quantity:
2
MRC:
The direction in which the heat is discharged from the item.ABAX
Heat Delivery Direction:
Horizontal
MRC:
Indicates the type of outlet(s) provided for the discharge of heat.ABAY
Heat Discharge Outlet Type:
Stationary
MRC:
Indicates the device/s/ provided for the purpose of directing the flow of heat.ABAZ
Heat Directing Device:
Fixed louver
MRC:
The different speeds at which the item may be operated.ABBB
Speed Adjustments:
Single speed
MRC:
The maximum rated capacity of air flow moved through the item.ABBD
Maximum Air Flow Rate:
1650.0 cubic feet per minute
MRC:
Indicates the type of air the item is designed to circulate.ABBE
Circulated Air Type:
Heated
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
36.000 inches
MRC:
A linear measurement from the surface to a specified inner point on an item,in distinction from height.AEJZ
Depth:
43.000 inches
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Gasoline engine
MRC:
Indicates the type of device which controls the operation of the item.ALYC
Operating Control Type:
Thermostatic
MRC:
Indicates the type of heating element provided.BDXJ
Heating Element Type:
Combustion chamber
MRC:
The means used for purposes of igniting.BLJC
Ignition Method:
Pilot
MRC:
The chemical compound or mechanical mixture properties of which the inclosure is fabricated.CQSJ
Inclosure Material:
Steel
MRC:
The amount of fuel the item is rated to consume per hour.CQTY
Fuel Consumption Rate Per Hour:
4.0 gallons
MRC:
The rate of heat delivery of the item.CQXD
Heat Delivery Rate:
250000.0 british thermal unit
MRC:
The amount of fuel that the integral tank will hold.CRJT
Integral Fuel Tank Capacity:
16.0 gallons
MRC:
The means by which the fuel is fed to the item.CSGC
Fuel Feed Method:
Gravity
MRC:
Indicates the type of fuel(s) for which the item is designed.FUEL
Fuel Type:
91/96 octane gasoline
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
46.000 inches
MRC:
A numeric value which represents a positive whole value without regard to any unit of measure.NMBR
Quantity:
1
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Paint
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-h-11049 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).