Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
mil-k-43359
Πληροφορίες ανταλλακτικού
W/tilting handle on either side and for naval shipboard use
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Steam Jacketed Kettle
Κωδικός ονόματος στοιχείου:
08416
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Table
MRC:
Indicates the type of heat control included on the item.ABJM
Heat Control Type:
Thermostat
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
25.250 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The nominal rated pressure that an item can be expected to withstand without rupture.ADTD
Pressure Rating:
10.0 pounds per square inch
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+150.0/+270.0 degrees fahrenheit
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
440.0 pounds per hour wet
MRC:
An indication of whether or not a cover is provided.AQHT
Cover:
Provided
MRC:
A measurement of the capacity of an item.BBLT
Capacity Rating:
5.0 gallons
MRC:
An indication of whether or not a tilting feature is included.BBXF
Tilting Feature:
Included
MRC:
The rated power that an item can safely consume or provide.BDWW
Wattage Rating:
6.0 kilowatts
MRC:
Indicates the type of heating element provided.BDXJ
Heating Element Type:
Electric
MRC:
An indication of whether or not a safety valve is included.BGXL
Safety Valve:
Included
MRC:
Indicates the type of steam inclosure provided.BHPH
Steam Inclosure Type:
Fully jacketed
MRC:
The length of a straight line which passes through the center of an inner container,and terminates at the circumference.BHPJ
Inner Container Diameter:
17.000 inches
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Supp
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel, stainless
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
SPEC-IF-ICN-SNRE
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
Ii type and 7 size
MRC:
The technical differentiating characteristic/s/ of an item of supply which depart/s/ from the text of a specification or a standard in that it represents a selection of characteristics stated in the specification or standard as being optional,or a variation from one or more of the stated characteristics,or an additional characteristic not stated in the specification or standard.ZZZW
Departure From Cited Document:
Nsu approved/navsea nswccd, 4march2005
MRC:
The variation when the item is in conformity with a type designator covered by a specification or standard,except in regard to one or more technical differentiating characteristics.ZZZX
Departure From Cited Designator:
As modified by o/a h and voltage rating