Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
nav-5-lt
Πληροφορίες ανταλλακτικού
For naval shipboard use
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Food Mechanical Freezer
Κωδικός ονόματος στοιχείου:
35636
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
27.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
64.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
33.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The rated horsepower of the prime mover.AHZX
Prime Mover Horsepower Rating:
0.250
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Commercial
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
115.0 pounds per hour wet
MRC:
The number of alternating current winding phase(s).ANSA
Winding Phase:
Single
MRC:
The means used to operate the item.APHE
Operation Method:
Any acceptable
MRC:
The number of complete alternating current cyclic changes,per unit of time,for which the item is rated.APNB
Ac Frequency Rating:
60.0 hertz
MRC:
Indicates the type of unit.APQB
Unit Type:
Reach-in
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
The number of doors provided.ATSZ
Door Quantity:
1
MRC:
Indicates the type of condenser.AWLP
Condenser Type:
Hermetically sealed
MRC:
The element,compound,or mixture of which the outside shell is fabricated,excluding any surface treatment.AYSX
Outside Shell Material:
Steel, corrosion resisting
MRC:
Indicates the location of the hinge/s/ on the item.AYTC
Hinge Location:
Right side
MRC:
An indication of whether or not an evaporator is included.AZAA
Evaporator:
Included
MRC:
Indicates the type of cooling for which the condenser is designed.AZAD
Condenser Cooling Type:
Air
MRC:
The number of condenser units provided.AZAE
Condenser Unit Quantity:
1
MRC:
Indicates the location of the condenser unit.AZAQ
Condenser Unit Location:
Integral
MRC:
Indicates the type of evaporator unit.AZEA
Evaporator Unit Type:
Forced air-cooling
MRC:
A measurement of the capacity of an item and its location.BBDY
Capacity And Location:
4.000 cubic feet storage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Any acceptable
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
SPEC-IF-ICN-SNRE
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
5 size and 1 style and ii type
MRC:
The technical differentiating characteristic/s/ of an item of supply which depart/s/ from the text of a specification or a standard in that it represents a selection of characteristics stated in the specification or standard as being optional,or a variation from one or more of the stated characteristics,or an additional characteristic not stated in the specification or standard.ZZZW
Departure From Cited Document:
Nsu approved/navsea nswccd, 4march2005
MRC:
The variation when the item is in conformity with a type designator covered by a specification or standard,except in regard to one or more technical differentiating characteristics.ZZZX
Departure From Cited Designator:
As modified by spare parts and tools