Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
pd20-55m0d2
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Fixed Attenuator
Κωδικός ονόματος στοιχείου:
14224
MRC:
The primary application for which the item is designed.AAFS
Application Design:
Transmission line
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Aluminum
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular, terminal/terminals on opposite surfaces
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.360 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.700 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.850 inches
MRC:
The number of holes/slots or studs provided for attaching the item to a surface.ADAE
Mounting Hole/stud Quantity:
4
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.240 inches
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.25
MRC:
The total opposition (resistive and reactive) which the item offers to the admittance of an entering flow of alternating current,expressed in ohms.AHTY
Input Impedance Rating In Ohms:
50.0
MRC:
The total opposition /resistive and reactive/ which the output of the item provides to match,for maximum transfer of energy,the input impedance of another item,expressed in ohms.AHTZ
Output Impedance Rating In Ohms:
50.0
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
Tnc
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
5.0 watts peak
MRC:
The decrease in the strength of the radio frequency signals,expressed in decibels.AJDK
Rf Signal Attenuation In Decibels:
10.0
MRC:
The minimum and maximum values of the frequency range in which the voltage standing wave ratio is specified.AKNK
Voltage Standing Wave Ratio Frequency Range:
+10.0/+100.0 megahertz
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the mounting facility.ALBL
Mounting Facility Thread Size And Series/type Designator:
0.112-40 unc
MRC:
Indicates the type of connection per function.ASZN
Connection Type Per Function:
Female output and female input
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded hole
MRC:
Indicates the type and number of terminal(s) for providing electrical connection.BBHS
Terminal Type And Quantity:
3 connector
MRC:
The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
Frequency Range:
Between 10.000 megahertz and 100.000 megahertz
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
06845-2055453-0701 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)