Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
005479
Πληροφορίες ανταλλακτικού
One primary winding; eleven secondary windings, neutral tap on first through ninth secondariesone primary winding; eleven secondary windings, neutral tap on first through ninth secondaries
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Power Transformer
Κωδικός ονόματος στοιχείου:
32496
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not establishednot established
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.375 inches single mounting facility single center group2.375 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.000 inches single mounting facility single center group2.000 inches single mounting facility single center group
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.125 inches single group and 0.125 inches single group and 0.187 inches single group0.187 inches single group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz single component400.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Three phase to three phase single componentthree phase to three phase single component
MRC:
Indicates the type of connecting windings in a transformer to be powered by two or three phase currents.ACZD
Transformer Winding Connection Type:
Delta-delta and delta-delta and delta-wyedelta-wye
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Internal shield brought out to terminal single componentinternal shield brought out to terminal single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.000 inches 3.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
2.750 inches 2.750 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 3.875 inches and 3.875 inches and 4.125 inches 4.125 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
170.0 degrees celsius170.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosedfully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Slot single groupslot single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 1 primary single component and 11 secondary single component11 secondary single component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
200.0 milliamperes dc single component 1st secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
200.0 milliamperes dc single component 2nd secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
200.0 milliamperes dc single component 3rd secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
200.0 milliamperes dc single component 4th secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
17.50 ac volts single component 1st secondary17.50 ac volts single component 1st secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
17.50 ac volts single component 3rd secondary17.50 ac volts single component 3rd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
17.50 ac volts single component 4th secondary17.50 ac volts single component 4th secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
17.50 ac volts single component 2nd secondary17.50 ac volts single component 2nd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
180.00 ac volts single component single primary and 180.00 ac volts single component single primary and 200.00 ac volts single component single primary and 200.00 ac volts single component single primary and 220.00 ac volts single component single primary220.00 ac volts single component single primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 connector, plug and 43 tab, solder lug