Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
0287390004
Μονάδα μέτρησης:
No qup EA
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Ceramic Diele Variable Capacitor
Κωδικός ονόματος στοιχείου:
00721
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rotary
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.300 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.157 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.265 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.275 inches
MRC:
A constant that represents the proportionate change in capacitance caused by a change in temperature,expressed in parts per million per degree celsius.AEBC
Tempurature Coefficient Of Capacitance In Ppm Per Deg Celsius:
-1500.0 single section
MRC:
The center to center distance between terminals parallel to the length of the item.AEBP
Center To Center Distance Between Terminals Parallel To Length:
0.200 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.AEBW
Center To Center Distance Between Mounting Facilities Parallel To Height:
0.248 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
0.200 inches
MRC:
The ratio of capacitive reactance to resistance,expressed at 25 degrees celsius.AECJ
Quality Factor At 25 Deg Celsius:
500.0
MRC:
A measurement taken at right angles to the length of the terminal,in distinction from thickness.AFWW
Terminal Width:
0.049 inches
MRC:
A measurement of the smallest dimension of the terminal,in distinction from length or width.AFWY
Terminal Thickness:
0.014 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
5895-01-121-3736 central, communications
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The torque required for the adjustment device.AXGR
Adjustment Device Torque:
Between 1.100 inch-ounces and 5.700 inch-ounces
MRC:
Direct current resistance between two conductors that are separated by an insulating material,measured at 25 degrees celsius.AXGT
Insulation Dc Resistance At 25 Deg Celsius:
10000.0 megohms
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
3 terminal
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
Between -40.0 degrees celsius and 85.0 degrees celsius
MRC:
The minimum and maximum values of the electrical capacitance measured between two specified points on the item,expressed in picofarads.CTGN
Capacitance Range In Picofarads:
+7.0/+35.0 single section
MRC:
The highest potential and type that may be applied to the item,at the highest operating temperature permissible without voltage derating.CTGP
Nonderated Voltage Rating And Type:
110.0 ac rms single section or 160.0 dc continuous single section
MRC:
The limits of capacitance change in percent at operating temperature from a stated value at 25 degrees celsius.CTGQ
Capacitance Change In Percent At Operating Tempurature From 25 Deg Celsius:
+6.00/+16.00 single section and -11.00/-6.00 single section
MRC:
Indicates the type and number of drive(s) provided for the adjustment device.CTGR
Adjustment Device Drive Type And Quantity:
2 slotted screw
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 printed circuit