Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
05f1132
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Power Supply
Κωδικός ονόματος στοιχείου:
00740
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.940 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
C-58 aircraft
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 2nd operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
115.0 ac pounds per hour dry 1st operating power rqmt and 230.0 ac pounds per hour with retaining chain 1st operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
115.0 ac pounds per hour dry 2nd operating power rqmt and 230.0 ac pounds per hour with retaining chain 2nd operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
23.0 dc volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
25.0 dc volts 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 1st operating power rqmt and 400.0 hertz 1st operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 2nd operating power rqmt and 400.0 hertz 2nd operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+50.0 degrees celsius
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 1st power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 2nd power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 2nd power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.5 dc amperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.5 dc amperes 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 1st power output