Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
10186172
Μονάδα μέτρησης:
No qup EA
Πληροφορίες ανταλλακτικού
X 10 magnifier for sweep rates to 20 nsec/div
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Oscilloscope
Κωδικός ονόματος στοιχείου:
00357
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
12.030 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.950 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.300 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.AFJK
Cubic Measure:
280.977 cubic inches
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
350.0 volts
MRC:
The number of beams provided on the item.ATES
Beam Quantity:
2
MRC:
The interval/s/ as indicated by the markings on the item.AWEC
Graduation Interval:
Graduated in v/div on y-axis; graduated in sec/div on x-axis
MRC:
The means of attaching the item.AXGY
Mounting Method:
Cradle in cabinet
MRC:
Designates the relative or proportionate dimensions of the screen.BGQK
Screen Size:
2.500 by 2 inches
MRC:
An indication of whether or not sweep circuits are included.BGQL
Sweep Circuits:
Included
MRC:
An indication of whether or not a generator driven feature is included.BGQM
Generator Driven Feature:
Included
MRC:
Indicates the type of sweep circuits provided.BGQN
Sweep Circuit Type:
Horizontal and vertical
MRC:
The range of complete cyclic changes,per unit of time,for which the sweep is rated.BGQP
Sweep Frequency Range:
+0.0/+15.0 megahertz
MRC:
The length of time consumed by a single trigger sweep.BGQQ
Single Trigger Sweep Duration:
Between 0.2 microseconds and 0.5 seconds
MRC:
The maximum absolute value for which the trigger sweep voltage is rated.BGRZ
Trigger Sweep Voltage Amplitude Rating:
250.0 volts
MRC:
An indication of whether or not a trigger sweep polarity switch is included.BGSB
Trigger Sweep Polarity Switch:
Included
MRC:
The distance between indicated pulse intervals shown on the screen of a trigger sweep designed item.BGSC
Trigger Sweep Marker Intervals:
0.2 usec; 0.5 usec; 1 usec; 2 usec; 5 usec; 10 usec; 20 usec; 50 usec; 0.1 msec; 0.2 msec; 0.5 msec; 1 msec; 2 msec; 5 msec; 10 msec; 20 msec; 50 msec; 0.1 sec; 0.2 sec; 0.5 sec
MRC:
An indication of whether or not an expanded sweep is provided.BGSD
Expanded Sweep:
Provided
MRC:
An indication of whether or not provisions for rating the deflection sensitivity through the amplifier are provided.BHDD
Amplifier Deflection Sensitivity Provision:
Not provided
MRC:
An indication of whether or not an input intensity modulation feature is provided.BHDH
Input Intensity Modulation Feature:
Not provided
MRC:
An indication of whether or not provisions for rating the direct connection to the plate deflection sensitivity is provided.BHDL
Plate Direct Connection Deflection Sensitivity Provision:
Not provided
MRC:
An indication of whether or not a frequency response rating is provided.BHDP
Frequency Response Rating:
Not provided
MRC:
An indication of whether or not amplifier input impedance rating is provided.BHDT
Amplifier Input Impedance Rating Provision:
Provided
MRC:
The total opposition (resistive and reactive) which the item offers to the y-axis input flow of alternating current.BHDX
Y-axis Input Impedance Rating:
1.0 megohms
MRC:
An indication of whether or not a calibrated screen scale is included.BHFF
Calibrated Screen Scale:
Included
MRC:
An indication of whether or not a trace storage tube is included.BHFH
Trace Storage Tube:
Not included
MRC:
An indication of whether or not camera recording device accommodations are provided.BHFT
Camera Recording Device Accommodation:
Not provided
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Supp
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Critical application: support equipment, b-1 aircraft; test set, mvs, an/tam-3a; missile, tow; tank, sheridan m-551
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
18876-10186172 manufacturers specification control
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Test set, elect. Equip.