Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
10221-0350
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
Πληροφορίες ανταλλακτικού
6frequency range 1.6 to 30.0 mhz; power output 1kw pep/avg; modes hi/low and auto bypass; rf drive power 60 watts for 1kw output with overdrive protection; tuning time 50 milisec; fault protected for input drive, thermal overload and vswr mismatch
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Radio Frequency Amplifier
Κωδικός ονόματος στοιχείου:
00446
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
24.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
21.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-30.0/+55.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/grc-212
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Free-standing
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
1.6 megahertz operating channel err-100 and 30.0 megahertz operating channel err-100
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
1.0 kilowatts output
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
60.0 watts input
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
47.0 single voltage and 63.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
115.0 single voltage and 230.0 single voltage
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Continuous operation at reduced power with redundant 600 watt power amp modules, ac/dc power supplies and cooling fans