Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
1028263t01028267
Πληροφορίες ανταλλακτικού
Furnished w/one single hinged-type door located in sliding sectional door, equipped w/two steam heaters w/elec motor driven, hangar is expandable to a miltiple hangar arrangement on either side of hangar, explosion-proof elec power wiring system, erection hand tools, akgf and akgg min.
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Ready-cut Prefabricated Building
Κωδικός ονόματος στοιχείου:
02393
MRC:
A nominal measurement taken at right angles to the length of an item,in distinction from thickness.AKGF
Width:
160.000 feet
MRC:
A nominal measurement of the longest dimension of an item,in distinction from width.AKGG
Length:
110.000 feet
MRC:
The element,compound,or mixture of which the floor is fabricated,excluding any surface treatment.AQJL
Floor Material:
Concrete
MRC:
Indicates the location of the door on the item.AYXP
Door Location:
End wall
MRC:
Indicates the type and number of doors furnished with the item.BGDY
Door Type And Quantity:
2 hinged single
MRC:
Indicates the type and number of doors furnished with the item.BGDY
Door Type And Quantity:
2 horizontal sliding sectional
MRC:
Indicates the type and number of doors furnished with the item.BGDY
Door Type And Quantity:
2 horizontal sliding single
MRC:
Indicates the location of an item which is insulated.BNJD
Insulation Location:
Uninsulated
MRC:
Indicates the location of the door opening.BPQL
Door Opening Location:
End wall
MRC:
A measurement from floor level to center clearance of the item.BXDB
Err Default:
Err default
MRC:
An indication of whether or not a partially paneled feature is included.BXDJ
Partially Paneled Feature:
Not included
MRC:
A measurement from the floor level to the top of the sidewall.BXDK
Err Default:
Err default
MRC:
The element,compound,or mixture of which the roof frame is fabricated,excluding any surface treatment.BXDL
Roof Framing Material:
Steel
MRC:
The element,compound or mixture of which the roof is fabricated,excluding any surface treatment.BXDN
Roof Material:
Steel
MRC:
The element,compound,or mixture of which the sidewall frame is fabricated,excluding any surface treatment.BXWP
Sidewall Framing Material:
Steel
MRC:
The element,compound,or mixture of which the outside sidewall is fabricated,excluding any surface treatment.BXWQ
Outside Sidewall Material:
Steel
MRC:
The element,compound,or mixture of which the inside sidewall is fabricated,excluding any surface treatment.BXWR
Inside Sidewall Material:
Steel
MRC:
The element,compound,or mixture of which the endwall frame is fabricated,excluding any surface treatment.BXWS
Endwall Framing Material:
Steel
MRC:
The element,compound,or mixture of which the outside endwall is fabricated,excluding any surface treatment.BXWT
Outside Endwall Material:
Steel
MRC:
The element,compound,or mixture of which the inside endwall is fabricated,excluding any surface treatment.BXWW
Inside Endwall Material:
Steel
MRC:
The element,compound,or mixture of which the floor frame is fabricated,excluding any surface treatment.BXWX
Floor Framing Material:
Any acceptable
MRC:
The element,compound,or mixture of which the foundation post(s) is fabricated,excluding any surface treatment.BXWY
Err Default:
Err default
MRC:
The element,compound,or mixture of which the ceiling is fabricated,excluding any surface treatment.BXXC
Err Default:
Err default
MRC:
The element,compound,or mixture of which the partition(s) is fabricated,excluding any surface treatment.BXXD
Err Default:
Err default
MRC:
The number of rooms provided.BXXF
Room Quantity:
1
MRC:
The number of door openings provided.BXXG
Err Default:
Err default
MRC:
Indicates the type of door opening provided.BXXH
Err Default:
Err default
MRC:
A measurement taken at right angles to the length of the door uprights.BXXJ
Err Default:
Err default
MRC:
A measurement from the bottom to the top of the door opening,in distinction from depth.BXXK
Err Default:
Err default
MRC:
A measurement taken at right angles to the length of the door.BXXL
Err Default:
Err default
MRC:
A measurement from the bottom to the top of the door,in distinction from depth.BXXM
Err Default:
Err default
MRC:
The number of shutters provided.BXXT
Shutter Quantity:
5
MRC:
The number of ventilator openings provided.BXXZ
Err Default:
Err default
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rigid frame gable
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-b-28543 government specification