Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
10b-1165
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Power Autotransforme Transformer
Κωδικός ονόματος στοιχείου:
36166
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
3.125 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
3.031 inches single mounting facility single center group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz single component and 2.0 kilohertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Three phase to three phase single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
8.125 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
3.875 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
105.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
6 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded hole single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary, variable autotransformer type single component
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.250 inches single group
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
1.75 amperes dc single component single primary output
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
0.00 ac volts single component single primary output and 240.00 ac volts single component single primary output
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
240.00 ac volts single component single primary input
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc single group
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
10 tab, solder lug