Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
10m25-109-1
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Refrigerating Water Chiller
Κωδικός ονόματος στοιχείου:
13452
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
8.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
10.750 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Refrigerant 12
MRC:
The installed position for which the item is designed.ADSM
Mounting Position:
Horizontal
MRC:
The element,compound,or mixture of which the shell is fabricated.AEUG
Shell Material:
Brass
MRC:
The type of water with which the item is designed to be used.AWCD
Water For Which Designed:
Fresh
MRC:
Indicates the operating location of the refrigerant.AWCK
Refrigerant Operating Location:
In tubes
MRC:
The amount of effective cooling area.AWGF
Effective Cooling Area:
114.000 square feet
MRC:
Indicates the type of tube provided.AWGH
Tube Type:
Straight
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Copper
MRC:
A measurement of the longest dimension of the shell,in distinction from width.AWKR
Shell Length:
6.500 feet
MRC:
The length of a straight line which passes through the center of the shell,and terminates at the outside circumference.AWKS
Shell Outside Diameter:
10.750 inches
MRC:
The number of water connections provided.AWKT
Water Connection Quantity:
2
MRC:
Indicates the type of water connection/s/.AWKW
Water Connection Type:
Flange
MRC:
The number of refrigerant inlet connections provided.AWKX
Refrigerant Inlet Connection Quantity:
1
MRC:
Indicates the type of refrigerant inlet connection/s/.AWKY
Refrigerant Inlet Connection Type:
Tube
MRC:
Designates the size of the water connection.AWKZ
Water Connection Size:
2-1/2 in. Ips
MRC:
Designates the size of the refrigerant inlet connection.AWLA
Refrigerant Inlet Connection Size:
1-3/8 in, od
MRC:
The number of refrigerant outlet connections provided.AWLB
Refrigerant Outlet Connection Quantity:
1
MRC:
Indicates the type of refrigerant outlet connection/s/.AWLC
Refrigerant Outlet Connection Type:
Tube
MRC:
Designates the size of the refrigerant outlet connection.AWLD
Refrigerant Outlet Connection Size:
2-5/8 in. Od
MRC:
The maximum internal pressure,determined by destruction tests at which the item can be expected to rupture.AWWG
Refrigerant Side Test Minimum Pressure:
225.0 pounds per square inch
MRC:
The maximum internal pressure,determined by destruction tests at which the item can be expected to rupture.AWWH
Water Side Test Minimum Pressure:
225.0 pounds per square inch