Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
128scav620-1
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Non Wire Wound Variable Resistor
Κωδικός ονόματος στοιχείου:
37406
MRC:
The number of individual elements.AAPN
Section Quantity:
2
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical bushing mounted
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.063 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
0.969 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.250 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
1.500 inches
Mounting Bushing Length:
0.250 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.563 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.094 inches
Undercut Diameter:
0.125 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round, stepped
MRC:
Indicates the type of shaft bearing/s/ furnished.AEDZ
Shaft Bearing Type:
Bearing
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Dual concentric
MRC:
That part of the total rotational travel of the actuator that produces a change in output,expressed in degree angular rotation.AEFH
Effective Electrical Rotation In Deg Angular Rotation:
320.0
MRC:
The maximum amount of turning force required to initiate the actuator movement.AEFK
Maximum Starting Torque:
2.00 inch-ounces
MRC:
The maximum amount of force requred to maintain actuator movement.AEFL
Maximum Running Torque:
2.00 inch-ounces
MRC:
The maximum amount of turning force that can be applied through the operating shaft with0ut damage to the stops.AEFM
Maximum Stop Torque:
128.00 inch-ounces
MRC:
Indicates the location of a mechanical device which prevents the turning of the item on its mounted surface,expressed by the twelve hour clock designation.AEFN
Nonturn Device Location:
At 12 oclock
MRC:
The linear measurement of the distance from the actuator centerline to the centerline of the nonturn device.AEFP
Nonturn Device Radius:
0.359 inches
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Rugged
Undercut Length:
0.500 inches
MRC:
The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.AJYN
Screw Thread Diameter:
0.375 inches
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.AJYP
Screw Thread Series Designator:
Unef
MRC:
The number of screw threads on the item per linear inch measured on a line parallel to the thread axis,including incomplete threads.AJYQ
Screw Thready Qty Per Inch (tpi):
32.0
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Radially positioned over less than half the circumference
MRC:
The means of attaching the item.AXGY
Mounting Method:
Standard bushing
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
100.000 kilohms all sections
MRC:
The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.CQCK
Rotary Actuator Travel In Angular Deg:
320.0
MRC:
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
Function Conformity Tolerance Per Section:
-3.00/+3.00 all sections
MRC:
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
Function Conformity Tolerance Per Section:
-3.00 to 3.00 all sections
MRC:
The ambient temperature at which the power dissipation of each section is derated to zero percent of the full rated power.CQGN
Ambient Tempurature In Deg Celsius Per Section At Zero Percent Rated Power:
125.0 all sections
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
1.5 7th secondary pattern
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
3.0 7th secondary finish
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
1.5 free air 2nd section
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
3.0 free air 1st section
MRC:
The fidelity of the relationship between the actual function characteristics and the theoretical function per section.CRGM
Function Conformity Per Section:
All sections independent linearity
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-5.0/+5.0 all sections
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-5.0 to 5.0 all sections
MRC:
The feature that controls the actuator travel.CRSX
Actuator Travel Control Feature:
Stops
MRC:
The specified mathematical relation per section between the terminal resistance,or output ratio,and the rotation of the actuator.CSBX
Function Characteristic Per Section:
All sections linear
MRC:
A constant that represents the proportionate change in resistance of the wire per section of which the resistance element of a resistor is wound,expressed in parts per million per degree celsius.CSCY
Tempurature Coefficient Of Resistance Wire Per Section In Ppm Per Deg Celsius:
-20.0/+20.0 all sections
MRC:
A constant that represents the proportionate change in resistance of the wire per section of which the resistance element of a resistor is wound,expressed in parts per million per degree celsius.CSCY
Tempurature Coefficient Of Resistance Wire Per Section In Ppm Per Deg Celsius:
-20.0 to 20.0 all sections
MRC:
The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
60.0 all sections
MRC:
The measured weight of an item unencumbered by packaging or packing material.PKWT
Unpackaged Unit Weight:
1.25 ounces
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 turret