Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
1303-00-cfn5
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Refrigeration Condenser
Κωδικός ονόματος στοιχείου:
36880
MRC:
The refrigeration capacity of the item as rated by industry,expressed in tons per hour.AAYE
Refrigeration Flow Rate In Tons Per Hour:
5.000
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
42.410 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.880 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Refrigerant r134a
MRC:
The element,compound,or mixture of which the shell is fabricated.AEUG
Shell Material:
Steel
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Marine pack
MRC:
The element,compound,or mixture of which the head is fabricated,excluding any surface treatment.ARGE
Head Material:
Bronze
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
24
MRC:
The type of water with which the item is designed to be used.AWCD
Water For Which Designed:
Fresh
MRC:
The number of passes provided.AWGE
Pass Quantity:
4
MRC:
The amount of condensing surface area.AWGG
Condensing Surface Area:
42.240 square feet
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Copper nickel alloy
MRC:
An indication of whether of not the tube(s) is provided with fins.AWGL
Tube Fin:
Provided
MRC:
A measurement of the longest dimension of the shell,in distinction from width.AWKR
Shell Length:
33.125 inches
MRC:
The length of a straight line which passes through the center of the shell,and terminates at the outside circumference.AWKS
Shell Outside Diameter:
6.000 inches
MRC:
Indicates the type of water connection/s/.AWKW
Water Connection Type:
Threaded pipe
MRC:
The number of refrigerant inlet connections provided.AWKX
Refrigerant Inlet Connection Quantity:
1
MRC:
Indicates the type of refrigerant inlet connection/s/.AWKY
Refrigerant Inlet Connection Type:
Any acceptable
MRC:
Designates the size of the water connection.AWKZ
Water Connection Size:
1.0 inch o.D.
MRC:
Designates the size of the refrigerant inlet connection.AWLA
Refrigerant Inlet Connection Size:
1 inch square x 1.875 inches long, elbow connection
MRC:
The number of refrigerant outlet connections provided.AWLB
Refrigerant Outlet Connection Quantity:
1
MRC:
Indicates the type of refrigerant outlet connection/s/.AWLC
Refrigerant Outlet Connection Type:
Any acceptable
MRC:
Designates the size of the refrigerant outlet connection.AWLD
Refrigerant Outlet Connection Size:
1.500 inch o.D. X 1.000 inch i.D. X 1.188 inches long
MRC:
The maximum internal pressure,determined by destruction tests at which the item can be expected to rupture.AWWG
Refrigerant Side Test Minimum Pressure:
250.0 pounds per square inch
MRC:
The maximum internal pressure,determined by destruction tests at which the item can be expected to rupture.AWWH
Water Side Test Minimum Pressure:
200.0 pounds per square inch
MRC:
Indicates the type of cooling.AYTS
Cooling Type:
Water
MRC:
The rated capacity of water flow moved through the item.CWTS
Water Flow Rate:
18.0 gallons per minute