Αριθμός ανταλλακτικού:
13u33-76l69
Πληροφορίες ανταλλακτικού
Additional actuator voltage 110.0 at 50 hertz
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Motor Starter
Κωδικός ονόματος στοιχείου:
00905
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
12.594 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.344 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.312 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
208.0 volts and 220.0 volts and 440.0 volts and 550.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 25.0 hertz and 60.0 hertz
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Magnetic
MRC:
Indicates the performance capability of the item or component.AGLD
Performance Type:
Semiautomatic
MRC:
A designation indicating the size by which the item is commercially known and/or identified.AJXE
Size Designator:
3
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Three 11/32 in. Diameter mtg holes, one hole centered at top, two bottom holes 4.0 in. From ctr to ctrwith top hole 11 in. From ctr line of bottom holes
MRC:
An indication of the characteristic of the operating voltage.ANCN
Operating Voltage Characteristic:
Full
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
50.000
MRC:
The voltage required to actuate the item.ANDE
Actuator Voltage:
110.0 ac and 120.0 ac
MRC:
Indicates the type of load for which the item is protected.ANDW
Load Protection Type:
Overload or undervoltage release
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Open
MRC:
An indication of whether or not the item is designed in conformance with the national electrical manufacturers association (nema) standards.ANQC
National Electrical Manufacturers Association Standards Design:
Designed per nema std
MRC:
An indication of the various functional switching positions.ANRK
Switch Functional Positions:
Reset
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0