Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
142307-0001
Πληροφορίες ανταλλακτικού
Four filtered functions, four unfiltered function
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Band Pass Filter
Κωδικός ονόματος στοιχείου:
00209
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.430 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.760 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.460 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.250 inches
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+10.0/+500.0
MRC:
The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.300 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
70.0 hercules no.5599.1 pulses per second70.0 hercules no.5599.1 two phase to two phase70.0 hercules no.5599.1 two phase to three phase70.0 hercules no.5599.1 hertz
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms 1st band pass50.0 ohms 2nd band pass50.0 ohms 3rd band pass50.0 ohms 4th band pass
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms 1st band pass50.0 ohms 2nd band pass50.0 ohms 3rd band pass50.0 ohms 4th band pass
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 1st band pass 1st function inductance-capacitance 2nd band pass 2nd function inductance-capacitance 3rd band pass 3rd function inductance-capacitance 4th band pass 4th function
MRC:
The ratio of the maximum to the minimum voltage of the standing wave per function. the larger relative portion is given,the lower value having an implied /not given/ value of one /unity/.AHBZ
Voltage Standing Wave Ratio Per Function:
1.5 1st band pass1.5 2nd band pass1.5 3rd band pass1.5 4th band pass
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
16 terminal
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Moisture resistant and shock resistant
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
4.0 1st band pass4.0 2nd band pass4.0 3rd band pass4.0 4th band pass
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
4 pin input 1st function4 pin output 2nd function
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
45.00 megahertz 1st band pass 1st function and 68.00 megahertz 1st band pass 1st function and 72.00 megahertz 1st band pass 1st function and 95.00 megahertz 1st band pass 1st function45.00 megahertz 2nd band pass 2nd function and 68.00 megahertz 2nd band pass 2nd function and 72.00 megahertz 2nd band pass 2nd function and 95.00 megahertz 2nd band pass 2nd function45.00 megahertz 3rd band pass 3rd function and 68.00 megahertz 3rd band pass 3rd function and 72.00 megahertz 3rd band pass 3rd function and 95.00 megahertz 3rd band pass 3rd function45.00 megahertz 4th band pass 4th function and 68.00 megahertz 4th band pass 4th function and 72.00 megahertz 4th band pass 4th function and 95.00 megahertz 4th band pass 4th function
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Aluminum
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
68.00 megahertz 1st band pass and 72.00 megahertz 1st band pass68.00 megahertz 2nd band pass and 72.00 megahertz 2nd band pass68.00 megahertz 3rd band pass and 72.00 megahertz 3rd band pass68.00 megahertz 4th band pass and 72.00 megahertz 4th band pass
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
1.0 1st band pass 1st function and 60.0 1st band pass 1st function1.0 2nd band pass 2nd function and 60.0 2nd band pass 2nd function1.0 3rd band pass 3rd function and 60.0 3rd band pass 3rd function1.0 4th band pass 4th function and 60.0 4th band pass 4th function
MRC:
The minimum and maximum values of frequency,per function,between which the voltage standing wave ratio is specified.CRBN
Voltage Standing Wave Ratio Frequency Limits Per Function:
68.0 hercules no.5599.1 pulses per second and 72.0 hercules no.5599.1 pulses per second68.0 hercules no.5599.1 two phase to two phase and 72.0 hercules no.5599.1 two phase to two phase68.0 hercules no.5599.1 two phase to three phase and 72.0 hercules no.5599.1 two phase to three phase68.0 hercules no.5599.1 hertz and 72.0 hercules no.5599.1 hertz
MRC:
The metallic,nonmetallic,and/or chemical properties with which the body is plated,dipped and/or coated. the treatment is designed to protect the body surface/s/ and cannot be wiped off.CRST
Body Surface Treatment:
Nickel
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Contact surfaces gold
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Gold
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular terminal/terminals on one surface