Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
15001
Πληροφορίες ανταλλακτικού
Offset rotary vane design
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Rotary Vacuum Pump Unit
Κωδικός ονόματος στοιχείου:
29904
MRC:
The power required to start and operate the item at the actual rated capacity,including all accessories.AAXW
Brake Horsepower Required:
0.333
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
2
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Items furnished as accessories which are not specified elsewhere.ABFF
Furnished Items:
Electric power cable and inlet filter and quantity sight gage
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
15.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
9.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.625 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The cooling medium used to maintain the required operating temperature of the item.ACZV
Cooling Medium:
Oil
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The element,compound,or mixture of which the pump body is fabricated,excluding any surface treatment.AENE
Pump Body Material:
Aluminum alloy
MRC:
Indicates the type of pumping element included on the item.AENG
Pumping Element Type:
Sliding vane
MRC:
The device which prevents or reduces the amount of condensable vapors from entering and contaminating the item.AEQG
Vapor Condensation Preventative Device:
Gas ballast valving
MRC:
The volume of air passed per unit of time through an item.AEQH
Air Displacement Rate:
4.0 cubic feet per minute in free air
MRC:
The minimum temperature at which the item is designed to operate.AEQJ
Minimum Operating Temp:
32.0 degrees fahrenheit
MRC:
An indication of the system for which the item is designed.AERP
System Design:
Noncorrosive
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
2.2
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Lockout for checking refrigerant leaks
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0