Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
1611as863
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Variable Attenuator
Κωδικός ονόματος στοιχείου:
00838
MRC:
The primary application for which the item is designed.AAFS
Application Design:
Transmission line
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Irregular
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.380 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.440 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
Between 1.183 inches and 1.193 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-65.0/+100.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Countermeasures set an/dlq-3 (v)
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
2.50
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
Sma
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
Mounting Facility Screw Thread Series Designator:
Unc
MRC:
The overall limits of decrease of the amplitude ratio of a signal between the input and output of the item,expressed in decibels.ASYD
Overall Attenuation Range In Decibels:
+2.5/+4.0
MRC:
The frequency at which the attenuation accuracy was measured.ASYE
Attenuation Accuracy Reference Frequency:
4.0 gigahertz
MRC:
The means by which the attenuation can be varied from the minimum to the maximum setting.ASYF
Attenuation Variation Method:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 threaded hole
MRC:
The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
Frequency Range:
Between 1.000 gigahertz and 18.000 gigahertz
MRC:
The number of mounting threads on the item measured on a line parallel to the thread axis,including incomplete threads.CGGK
Mounting Thread Quantity:
32 per inch
MRC:
Indicates the type and number of facilities for adjusting the item.CQTQ
Adjustment Device Type And Quantity:
1 electronic, voltage controlled
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Two position in-line
MRC:
The nominal length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.CRYY
Mounting Facility Screw Thread Diameter:
0.138 inches
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Pin ext surface gold
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Gold
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 connector, coaxial, female and 1 connector, coaxial, male and 2 pin
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas, waveguides, and related equip.