Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
165-065
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Motor-tachometer Generator
Κωδικός ονόματος στοιχείου:
28454
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
1.060 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
3.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
1.060 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.1242 inches single end
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac input
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
8000.0 feet
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Totally enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Face
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 threaded hole
MRC:
Indicates the type of excitor provided.AYHE
Excitor Type:
Separately excited
MRC:
The speed at which the calibration is determined,expressed in revolutions per minute.BFLQ
Calibration Speed In Rpm:
1000.0
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Air to air cooled
MRC:
An indication of the type of calibration voltage output,expressed in volts.BKPC
Calibration Voltage Output Type In Volts:
0.5 ac
MRC:
Indicates the torque rating,and its type.BKPH
Torque Rating And Type:
0.6 inch-ounces stalled
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Commercial
MRC:
Indicates the type of control field voltage and its rating,expressed in volts.BKPS
Control Field Voltage Type And Rating In Volts:
36.0 ac
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
2.750 watts output
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.313 inches single end
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
0.0 operating degrees celsius and 85.0 operating degrees celsius
MRC:
The length of a straight line which passes through the center of a mounting facility circle,and terminates at the circumference.CWFQ
Mounting Facility Circle Diameter:
0.812 inches
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
3600.0 single no load
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
115.0 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A1 single style single end
MRC:
The number of alternating current phases.FAAZ
Phase:
Single input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0 output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 wire lead