Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
17g450398-1
Πληροφορίες ανταλλακτικού
Hydraulic test bench
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Hydraulic System Comp Test Stand
Κωδικός ονόματος στοιχείου:
11017
MRC:
The amount of hydraulic fluid required to operate the item.AAYJ
Hydraulic Fluid Flow Rate:
5.0 gallons per minute
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Aircraft hydraulic system
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Fixed
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
An indication of whether or not an accumulator is included.AYJM
Accumulator:
Not included
MRC:
The pressure at which an item is designed to operate.BGST
Pressure Rating:
Between 4000.0 pounds per square inch and 6000.0 pounds per square inch
MRC:
An indication of whether or not a design feature for testing engine driven hydraulic pumps is included.CGYK
Engine Driven Hydraulic Pump Testing Design Feature:
Not included
MRC:
An indication of whether or not a pressure manifold subcircuit(s) is included.CGYM
Pressure Manifold Subcircuit:
Not included
MRC:
An indication of whether or not a filtering system is included.CHGQ
Filtering System:
Not included
MRC:
An indication of whether or not a pressure and suction hose are included.CHGR
Pressure/suction Hose:
Not included
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Dual system, manually operated, stationary test bench with a stainless steel cabinet; uses depot 4000 psi and6000 psi hydraulic manifolds for hydraulic pressure and flow; includes all necessary hyrdaulic filters, regulators, pressure gauges, flow meters, reliefvalves and control valves; all pressure gauges and flow meters have analog and digital readouts; includes built-inelectrical dc power supply and duel servo controlers with lvt feedback; hydraulic fluid per mil-h-83282; fluid temp +50 to 275 degrees f; flow vs pressure: 5 gpm at 6000 psi, 30 gpm at 4000 psi, 60 gpm at 500 psi; height 72 inches, width 120 inches, depth 49 inches
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to functionally test all c-17a hyrdaulic lru's except pumps
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Serd number 450398