Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
212-075-302-1
Πληροφορίες ανταλλακτικού
Weapon system essential
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Power Autotransforme Transformer
Κωδικός ονόματος στοιχείου:
36166
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.870 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
320.0 hertz single component and 522.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
Indicates the type of drive provided for the adjustment device.ACZU
Adjustment Device Drive Type:
Shaft single component
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.750 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Wsd: helicopter, utility/search and recovery uh-1n; helicopter, advance attack ah-1w
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary, variable autotransformer type single component
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
W/switch
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.375 inches single group
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The means provided and number of adjustments included on the item.CTHD
Adjustment Method And Quantity:
1 adjustable control single component
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
115.00 ac volts single component single primary input
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
25.00 ac volts single component 1st primary output
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
40.00 ac volts single component 2nd primary output
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
60.00 ac volts single component 3rd primary output
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
85.00 ac volts single component 4th primary output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 threaded stud