Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
2271278
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Meter Movement Relay
Κωδικός ονόματος στοιχείου:
03884
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
4
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Solder lug
MRC:
The standard of valuation as represented by the inscription.ABWC
Scale Unit Of Measure Inscription:
Amperes
MRC:
Equal or unequal distances between graduations representing values of measurement on a scale.ABWF
Scale Linearity:
Nonlinear
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
10
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dust tight
MRC:
The hue or tint of the light emitted from that portion of the item which surrounds the inscription on the item.AETT
Inscription Background Color:
Clear
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Three no. 4/0.112 in./-40 thd mtg studs spaced 120 degrees apart on a 1.220 in. Radius
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
50.0 volts
MRC:
The minimum and maximum numeric values representing the measurement coverage of a scale.ANSZ
Scale Measurement Range:
+0.0/+75.0
MRC:
The number and combination/s/ of the basic contact forms,in the order of assemblage,which make up the switching structure of the main contact/s/.APDY
Main Contact Form Arrangement:
1c
MRC:
Indicates the type of current used by the main contact/s/.APEB
Main Contact Current Type:
Dc
MRC:
The current rating of the main contact/s/.APEC
Main Contact Current Rating:
200.0 milliamperes
MRC:
Indicates the type of current used in the meter movement.APGN
Meter Movement Current Type:
Dc
MRC:
The amount of voltage required to operate the meter movement,expressed in volts.APGP
Meter Movement Voltage In Volts:
0.050
MRC:
An indication of the minimum and maximum amount of current used in the meter movement.APGR
Meter Movement Current Range:
+0.0/+75.0 amperes
MRC:
An indication of the direction of the meter movement reading range.APGT
Meter Movement Range Direction:
Left to right
MRC:
Indicates the type of mount utilized to support the meter.APMR
Meter Mounting Type:
Flush
MRC:
An indication of the specific condition that causes the contacts to close.APMT
Contact Closing Condition:
Increase value
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Provided
MRC:
Indicates the type of lock in device provided.APNS
Lock In Device Type:
Locking coil
MRC:
The means by which the item is released.APNT
Release Method:
Manual and deenergize lock-in coil
MRC:
The length of a straight line which passes through the center of the mounting flange,and terminates at the circumference.APTE
Mounting Flange Diameter:
2.800 inches
MRC:
The length of a straight line which passes through the center of the meter body and terminates at the circumference.APTF
Meter Body Diameter:
2.155 inches
MRC:
A measurement between the mounting flange and the face of the item, in distinction from height.APTN
Meter Depth To Mounting Flange:
1.470 inches