Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
234966
Πληροφορίες ανταλλακτικού
End connections desinged for sub-plate sleeves
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Fluid Pressure Regulating Valve
Κωδικός ονόματος στοιχείου:
27565
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Brass
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
The element, compound,or mixture of which the stem is fabricated,excluding any surface treatment.ABEP
Stem Material:
Steel, corrosion resisting
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Air
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Unthreaded internal tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Socket
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.405 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
Seat Material:
Plastic, nylon resin
MRC:
The center to center distance.ADQR
Center To Center Distance:
0.562 inches
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Stem and integral disk
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Steel, corrosion resisting
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Automatic single stage
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The set /nonadjustable/ pressure of the media on the outlet side.AEWA
Outlet Pressure Setting:
300.0 pounds per square inch
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Included
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
250.0 degrees fahrenheit