Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
24730282983
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
Πληροφορίες ανταλλακτικού
Weighs 2 lbs; oper. Temp 0-50 degrees c; storage temp m40-p70 degrees c; 6 watts
NSN
Εθνικός αριθμός αποθέματος:
Κωδικός ονόματος στοιχείου:
16449
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.563 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.000 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Part of loral digital meter panel assembly, p/n 294828-01, for e/i loral afscn/cue, p/n an/fsq-15 (v)
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Window 1; front panel 1; analog board assembly 1; digital board assembly w/o bcd 1; digital board assembly w/bcd 1; case 1; analog connector package 1; digital connector package 1
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Digital display
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Panel
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-0.01/+0.01 at full scale single indicator single range
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
4.250 inches
MRC:
A measurement taken at right angles to the length of the meter body behind the mounting flange, in distinction from thickness.APSY
Meter Body Width Behind Mounting Flange:
4.000 inches
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
External
MRC:
Indicates the type of display provided.BFQN
Display Type:
Gas discharge tube
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
4-1/2
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.000/+19.999 volts, dc single indicator single range
Meter Body Height Behind Mounting Flange:
1.750 inches
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
2 connector, receptacle
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
117.0 ac
MRC:
The type and/or standard interface system with which the item is compatible.CTWZ
Interface Compatibility:
Bcd
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Compact, single range, 4 1/2 digit, bi-polar, high impedance instrument designed to indicate input dc voltage or current in one of 10 possible ranges; full scale count of 19999; basic measuring circuit is a high impedance bi-polar analog to digital converter that employs the dual slope integration method
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Scf-tm-bdh10-3, vol3, no.5
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular flush mtg