Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
26-1024-34
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Fluid Pressure Regulating Valve
Κωδικός ονόματος στοιχείου:
27565
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel, federal standard 66, aisi 303/sae 30303
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal boss
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Gasket seal
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
7/16-20 unjf
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACLK
First End Thread Class:
3b
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
Seat Material:
Plastic, polychlorotrifluoroethylene, mil-m-55028, kel-f-canceled
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Piston, spring loaded
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The means other than the end connection/s/ by which the item may be mounted.ADZJ
Mounting Facility:
Bracket
MRC:
The minimum to maximum limits of outlet pressure of the item.AEVA
Outlet Pressure Range:
+15.0/+2500.0 pounds per square inch
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Manual single stage
MRC:
The means used to manually adjust the item.AEVP
Manual Control Method:
Knob
MRC:
The seat design of the valve stem.AEVQ
Valve Stem Design:
Single seat
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
10000.0 pounds per square inch
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Included
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
Between -65.0 degrees fahrenheit and 165.0 degrees fahrenheit