Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
27067-2
NSN
Εθνικός αριθμός αποθέματος:
Κωδικός ονόματος στοιχείου:
00724
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
60 single component 1st winding
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
60 single component 2nd winding
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
128 single component 3rd winding
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.275 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.025 inches single mounting facility single center group
MRC:
Indicates the type of inductance included on the item.ACYF
Inductance Type:
Swinging
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
1.00 millihenries single component 3rd winding and 5.50 millihenries single component 3rd winding
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
375.00 microhenries single component 2nd winding and 750.00 microhenries single component 2nd winding
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
375.00 microhenries single component 1st winding and 750.00 microhenries single component 1st winding
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
80.0 kilohertz single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.600 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.290 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.310 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
155.0 degrees celsius
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
3 single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded hole single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component all winding and winding turns single component all winding
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Tinned wire leads
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.112 inches single group
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.02010 inches american wire gage single component 3rd winding
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.03589 inches american wire gage single component 1st winding
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.03589 inches american wire gage single component 2nd winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
250.0 milliamperes dc single component 2nd winding and 1.0 amperes dc single component 2nd winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
250.0 milliamperes dc single component 1st winding and 1.0 amperes dc single component 1st winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
80.0 milliamperes dc single component 3rd winding and 1.2 amperes dc single component 3rd winding
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.055 single component 1st winding
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.055 single component 2nd winding
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.650 single component 3rd winding
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc single group
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 wire lead