Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
2835870
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
Πληροφορίες ανταλλακτικού
Tubing wall construction can also be laminated
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Waveguide Assembly
Κωδικός ονόματος στοιχείου:
00305
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Internal, rectangular external, rectangular
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b first flange single connection facility
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand first flange single connection facility
MRC:
The angular measurement by which one part/section of a rigid item deviates from a straight line projection of an adjacent part/section,expressed in degrees.ACJL
Bend Angle In Deg:
90.0 fifth bend h-plane
MRC:
The angular measurement by which one part/section of a rigid item deviates from a straight line projection of an adjacent part/section,expressed in degrees.ACJL
Bend Angle In Deg:
90.0 first bend e-plane
MRC:
The angular measurement by which one part/section of a rigid item deviates from a straight line projection of an adjacent part/section,expressed in degrees.ACJL
Bend Angle In Deg:
90.0 fourth bend h-plane
MRC:
The angular measurement by which one part/section of a rigid item deviates from a straight line projection of an adjacent part/section,expressed in degrees.ACJL
Bend Angle In Deg:
90.0 second bend e-plane
MRC:
The angular measurement by which one part/section of a rigid item deviates from a straight line projection of an adjacent part/section,expressed in degrees.ACJL
Bend Angle In Deg:
90.0 third bend h-plane
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Seamless single tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
Flange Inside Width:
0.897 inches first flange and 0.903 inches first flange
Flange Inside Width:
1.003 inches second flange and 1.006 inches second flange
Flange Inside Height:
0.397 inches first flange and 0.403 inches first flange
Flange Inside Height:
0.503 inches second flange and 0.506 inches second flange
Flange Outside Width:
1.610 inches first flange and 1.640 inches first flange
Flange Outside Width:
1.610 inches second flange and 1.640 inches second flange
Flange Outside Height:
1.610 inches second flange and 1.640 inches second flange
Flange Outside Height:
1.610 inches first flange and 1.640 inches first flange
Flange Inside Diameter:
1.000 inches first flange and 1.060 inches first flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.423 inches first flange and 0.453 inches first flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.422 inches second flange and 0.453 inches second flange
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.169 inches second flange single connection facility and 0.172 inches second flange single connection facility
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.00
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.10
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
20.0 pounds per square inch gage
Waveguide Outside Width:
Between 0.996 inches and 1.004 inches
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.164 inches first flange single connection facility
Waveguide Inside Width:
Between 0.896 inches and 0.904 inches
Waveguide Inside Height:
Between 0.396 inches and 0.404 inches
Waveguide Outside Height:
Between 0.496 inches and 0.504 inches
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 threaded hole first flange single connection facility
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 unthreaded hole second flange single connection facility
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Choke type first flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Cover type second flange
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Rigid single tubing segment
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy all flange
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy single tubing segment
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Oxide film all tubing segment and flange outside surfaces
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc first flange single connection facility