Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
2925
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Insulation Breakdown Test Set
Κωδικός ονόματος στοιχείου:
16408
MRC:
Indicates the type of termination provided on the wire.ABCC
Wire Termination Type:
Clip and prod
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
14.560 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
11.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 115.0 volts and 230.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
A measurement of the longest dimension of a wire lead.AFSC
Wire Lead Length:
72.000 inches
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Bench
MRC:
Indicates the type of output current whether alternating,direct,or both.ANPN
Output Current Type:
Ac
MRC:
An indication of the type of meter.ANTH
Meter Type:
Ammeter and voltmeter
MRC:
The number of meters provided.ANTJ
Meter Quantity:
2
MRC:
An indication of the scale range.APSK
Scale Range:
+0.1/+12.0 milliamps and +0.0/+5.0 kilovolts
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The output voltage rating at which the item is designed to operate.AQYB
Output Voltage Rating:
Between 0.000 volts and 5000.000 volts
MRC:
The output current rating at which the item is designed to operate.AQYD
Output Current Rating:
12.000 milliamperes
MRC:
The number of test leads provided with the item.AQYL
Test Lead Quantity:
3
MRC:
The device provided to protect the circuit from an electrical overload condition.AQYM
Circuit Overload Protection Device:
Fuse
MRC:
The number of prods provided.ARYQ
Err Default:
Err default
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Includes 2925 hipot tester; safety probe w/6 ft lead p/n 102-050-913; high voltage clip w/6 ft lead p/n 102-055-913; ground return clip w/ 6 ft lead p/n 102-069-904; user manual; nist traceable certificate of conformance; standard 1 year warranty