Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
3101-1124p1
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Waveguide Assembly
Κωδικός ονόματος στοιχείου:
00305
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Internal, rectangular external, rectangular
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b first flange single connection facility
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand first flange single connection facility
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Seamless single tubing segment
MRC:
Indicates the type of twist as characterized by the method or manner by which the rotation of the cross-sectional axes of the tubing is affected.AHRW
Tubing Twist Type:
Straight twist single tubing segment
MRC:
The angle to which a rigid tubing has been intentionally rotated during manufacture or the maximum angle to which a twistable type tubing may be rotated,as measured in degrees of angular difference between the plane of a specific transverse dimension at one extremity of the tubing and the plane of the same dimension at the other extremity.AHRX
Tubing Twist Angle In Deg:
15.0 single tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
Flange Inside Width:
1.122 inches first flange
Flange Inside Width:
1.253 inches second flange
Flange Inside Height:
0.497 inches first flange
Flange Inside Height:
0.628 inches second flange
Flange Outside Width:
1.875 inches first flange
Flange Outside Width:
1.875 inches second flange
Flange Outside Height:
1.875 inches first flange
Flange Outside Height:
1.875 inches second flange
Flange Inside Diameter:
1.625 inches first flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.438 inches second flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.625 inches first flange
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.169 inches second flange single connection facility
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.02
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.07
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
5.0 pounds per square inch gage
Waveguide Outside Width:
1.250 inches
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.164 inches first flange single connection facility
Waveguide Inside Width:
1.122 inches
Waveguide Inside Height:
0.497 inches
Waveguide Outside Height:
0.625 inches
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 threaded hole first flange single connection facility
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 unthreaded hole second flange single connection facility
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Choke type first flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Cover type second flange
Waveguide Length:
5.000 inches
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible single tubing segment
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy single tubing segment
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Rubber single tubing jacket
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Internal surfaces silver and internal surfaces rhodium
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Enamel single tubing segment outside surfaces
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Silver all tubing segment and flange inside surfaces and rhodium all tubing segment and flange inside surfaces
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight type
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc first flange single connection facility
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Fire control radar equipment, except airborne