Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
3150816
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
Πληροφορίες ανταλλακτικού
8.5 to 9.6 ghz; attenuation 0.08 db/ft; neoprene or ethylene jacket; minus 10 to plus 70 degrees c operating temperature
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Waveguide Assembly
Κωδικός ονόματος στοιχείου:
00305
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Internal, rectangular external, rectangular
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b all flanges all connection facilities
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand all flanges all connection facilities
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Seamless single tubing segment
MRC:
Indicates the type of twist as characterized by the method or manner by which the rotation of the cross-sectional axes of the tubing is affected.AHRW
Tubing Twist Type:
Twistable single tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
Flange Inside Width:
1.118 inches all flanges and 1.126 inches all flanges
Flange Inside Height:
0.493 inches all flanges and 0.501 inches all flanges
Flange Outside Width:
2.480 inches all flanges and 2.520 inches all flanges
Flange Outside Height:
1.730 inches all flanges and 1.770 inches all flanges
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.480 inches all flanges and 0.520 inches all flanges
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.10
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
32 all flanges all connection facilities
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
15.0 pounds per square inch gage
Waveguide Outside Width:
Between 1.246 inches and 1.254 inches
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.164 inches all flanges all connection facilities
Waveguide Inside Width:
Between 1.118 inches and 1.126 inches
Waveguide Inside Height:
Between 0.493 inches and 0.501 inches
Waveguide Outside Height:
Between 0.621 inches and 0.629 inches
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
8 threaded hole all flanges all connection facilities
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Contact type all flanges
Waveguide Length:
Between 2.960 inches and 3.040 inches
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible single tubing segment
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy all tubing segment and flange
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Tubing internal surface and flange surface silver
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Silver
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Silver all flange all surfaces
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Silver single tubing segment inside surfaces
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight type
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc all flanges all connection facilities
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas, waveguides, and related equipment