Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
322b813-4
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
S Electrical Insulation Sleeving
Κωδικός ονόματος στοιχείου:
61626
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-55.0 degrees celsius
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Corrosion resistant and flame resistant and mildew resistant and solvent resistant and water resistant
Main Body Inside Diameter:
0.500 inches after unrestricted recovery
Main Body Inside Diameter:
1.500 inches as supplied
First Branch Inside Diameter:
0.120 inches after unrestricted recovery
First Branch Inside Diameter:
0.240 inches as supplied
Main Body Wall Thickness:
0.080 inches after unrestricted recovery
First Branch Wall Thickness:
0.040 inches after unrestricted recovery
Main Bodylength:
5.000 inches as supplied
Angle Between Main Body And First Branch Centerlines In Deg:
45.0 as supplied
Angle Between Main Body And First Branch Centerlines In Deg:
90.0 after unrestricted recovery
MRC:
The maximum rated load in tension applied in a longitudinal direction,per unit of cross-sectional area,that the material can withstand without rupture.CQBC
Min. Tensile Strength (psi):
1200 pounds per square inch
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Plastic, polyolefin, rt-1304, raychem corp
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic, polyolefin, rt-1304, raychem corp
MRC:
The maximum potential gradient the insulating material can withstand,per unit thickness,without rupture.UKBG
Dielectric Material Voltage Rating Per Unit Thickness:
200.0 volts per military /0.001 inch/