Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
400-mcd
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
Πληροφορίες ανταλλακτικού
Test breathing oxygen system flow regulators and transmitters, displays temperature and flow; +/- 0.2 percent accuracy; materials aluminum, steel, copper and plastic
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Flow Rate Indicating Me Test Set
Κωδικός ονόματος στοιχείου:
19100
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
24.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
30.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 85.0 volts and 264.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 47.0 hertz and 440.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Digital display with multifunction keypad to select operations
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
F-15 aircraft breathing oxygen system components
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Alternate operating
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel housing
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Multiple item w/housing
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Calibrate transmitters rate of flow, 10 ccm, 100 ccm and 1 lpm
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Provides means to calibrate the flowmeters in the follow msogs test stands p/n 3300230-6001 oxygen regulator test stand, p/n 3300232-6001 inlet valve test stand, p/n 3301270-6101 msogs concentrator test stand, p/n 3301271-6101 ms0gs monitor test stand
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
10.000 inches
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
T.O. 33d2-10-73-1, 33d2-10-74-1, 33d2-10-75-1 or 33d2-10-76-1 as reqd fapplicable test stand
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Flow calibration system