Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
41a37000-001
Αποστρατιωτικοποίηση:
Yes - DEMIL/MLI
Πληροφορίες ανταλλακτικού
Mfg name test set, line obstruction flow and leak, c/o console assembly 1; cable assembly 1; flexible hose assembly 3; quick disconnect, socket 1; quick disconnect, plug 1; reducer 1; id plate 1; id tag 3; sleeve 3
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Pneumatic System Compon Test Set
Κωδικός ονόματος στοιχείου:
62393
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
42.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
66.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
120.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
B-1b aircraft age, b-1b fuel system and environmental control system
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/housing
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Used to perform pneumatic leak testing of ecs and fuel systems on the b-1b aircraft
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Pressure gages range 0 to 200 psig; flowmeter range 0.06 to 126 scfm
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Test set is used to perform confidence leak check on the environmental control syste (ecs) to verify that the leakage from the pneumatic components, ducting or lines are within allowable limits; to test functional status of backup pressure regulators and shutoff valves and to test for pressure leak and line obstruction of the fuel system and the nitrogen pressure system
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
60.000 inches
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Serd41a37c
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Input power for test set supplied by nsn 6230-00-752-2082, gaseous nitrogen will be provided by nsn 3655-01-038-5125, the test unit will incorporate a low pressure system designed to accept air pressures up to 150 psig and regulate the output pressure in the range of 0 to 75 psig while measuring the flow rate over 0.1 scfm (o to 75 psig). The test medium air (air/gn2) shall be dry and filtered through a 200 micron filter