Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
5007
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Stop-check Valve
Κωδικός ονόματος στοιχείου:
05486
MRC:
Indicates the type of housing on the item that accommodates the stem packing or spring.ADSR
Bonnet Type:
Packing retaining
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
425.0 degrees fahrenheit single response
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Valve, nonpowered
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Manual
MRC:
The physical configuration of the flange.ARKN
Flange Shape:
Round all ends
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Flange all ends
MRC:
Designates the size of the valve.CCFG
Valve Size:
3.000 inches
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
200.0 pounds per square inch 1st response
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
400.0 pounds per square inch 2nd response
MRC:
The nominal length of a straight line which passes through the center of an item,and terminates at the outside circumference.CWCD
Outside Diameter:
8.125 inches all ends
MRC:
The face to face distance.CWCF
Face To Face Distance:
13.000 inches
MRC:
A nominal measurement of the smallest dimension of an item,in distinction from length or width.CWCK
Thickness:
0.938 inches all ends
MRC:
The design of the flange face.CWDF
Flange Face Design:
Plain all ends
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy body
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight through flanged ends
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Flow control device: stem
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.TMQY
Furnished Items And Quantity:
1 handwheel