Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
50166b
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Electric Thermal Drying Oven
Κωδικός ονόματος στοιχείου:
12824
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
60.000 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
500.0 degrees fahrenheit
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
30.000 inches
MRC:
An inside measurement from the bottom to the top of an item,in distinction from depth.AFMQ
Inside Height:
48.000 inches
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Fan, motor 1, shelves 3
MRC:
The means used to control the temperature of an item.BBWM
Tempurature Control Method:
Automatic
MRC:
The rated power that an item can safely consume or provide.BDWW
Wattage Rating:
30.0 kilowatts
MRC:
The means used to provide circulation.BHGT
Circulation Method:
Forced
MRC:
The number of cabinet doors provided.BJPB
Cabinet Door Quantity:
2
MRC:
The extent of work protection provided from the heat source.BLSN
Work Protection From Heat Source:
Complete
MRC:
The minimum and maximum limits of temperature at which the item is normally operated.BLSQ
Normal Operating Tempurature Range:
+100.0/+500.0 degrees fahrenheit
MRC:
An indication of whether or not a double wall constructed cabinet is provided.BLSR
Cabinet Double Wall Construction:
Provided
MRC:
An indication of whether or not an insulated cabinet is provided.BLST
Insulated Cabinet:
Provided
MRC:
An indication of whether or not a cabinet exhaust vent is provided.BLSX
Cabinet Exhaust Vent:
Provided
MRC:
An indication of whether or not an adjustable opening is provided.BLSY
Adjustable Opening:
Not provided
MRC:
An indication of whether or not a cabinet fresh air intake is provided.BLSZ
Cabinet Fresh Air Intake:
Provided
MRC:
An indication of whether or not a fresh air intake adjustable opening is provided.BLTB
Fresh Air Intake Adjustable Opening:
Not provided
MRC:
Indicates the type of thermometer provided with the item.BLTC
Thermometer Type:
Fluid
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
220.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
4 type