Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
5848-14e-steam
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
High Pressure Steam Boiler
Κωδικός ονόματος στοιχείου:
03292
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac or dc
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Boiler found onboard 210 ft wmec coast guard vessels
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
32.0 pounds per hour dry and 220.0 pounds per hour with retaining chain
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
0.5
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
Vertical
MRC:
Indicates the type of draft for which designed.ASND
Draft Type:
Forced
MRC:
Indicates the type of firing.ASQR
Firing Type:
Oil
MRC:
The means of attaching the item.AXGY
Mounting Method:
Floor
MRC:
The maximum pressure at which the item is designed to operate.BJDW
Maximum Operating Pressure:
30.0 pounds per square inch gage
MRC:
The amount of steam for which the item is rated.BLHL
Steam Capacity:
535.000 pounds per hour
MRC:
The number of oil burners provided with the item.BLHS
Oil Burner Quantity:
1
MRC:
An indication of whether or not waterwalls are provided with the item.BLHX
Waterwalls:
Not provided
MRC:
An indication of whether or not a forced circulation feature is provided.BLHY
Forced Circulation Feature:
Provided
MRC:
The means used for purposes of igniting.BLJC
Ignition Method:
Electrical
MRC:
An indication of whether or not a marine service design feature is provided.BLSG
Marine Service Design Feature:
Provided
MRC:
An indication of whether or not maintenance parts are provided with the item.BLSH
Maintenance Parts:
Not provided
MRC:
An indication of whether or not a packaged boiler is provided.BLSK
Packaged Boiler:
Provided
MRC:
An indication of whether or not a superheater is provided.BLSL
Superheater:
Not provided
MRC:
The number of alternating current phases.FAAZ
Phase:
Single