Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
5kh10kg22t
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Gearcase-motor
Κωδικός ονόματος στοιχείου:
01102
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
4.750 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
10.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
4.750 inches
MRC:
A measurement taken at right angles to the length of a keyway,in distinction from thickness.ABRR
Keyway Width:
0.188 inches single end
MRC:
A measurement from the top surface to the bottom of the keyway groove.ABRV
Keyway Depth:
0.094 inches single end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.625 inches single end
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac input
MRC:
A measurement of the longest dimension of a keyway,in distinction from width.AFYS
Keyway Length:
1.500 inches single end
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Counterclockwise single end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Open protected
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Induction-squirrel cage
MRC:
The means of attaching the item.AXGY
Mounting Method:
Pad
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 threaded stud
MRC:
The drive shaft position as related to the armature axis.BFLY
Geared Head Output Shaft Alignment Position:
Offset above parallel to shaft axis single end
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Natural convection ventilated
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Load
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Commercial
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Thermal protective device
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
1.875 inches single end
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
3.625 inches
MRC:
The nominal center to center distance between the mounting facilities parallel to the height.CWGD
Center To Center Distance Between Mounting Facilities Parallel To Height:
3.625 inches
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
1.900 single input
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
115.0 line to neutral single input
MRC:
The speed rating of the geared head output shaft(s).CWHK
Geared Head Output Shaft Speed Rating:
0.100 single revolutions per minute single end
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A9 single style single end
MRC:
The number of alternating current phases.FAAZ
Phase:
Single input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 input
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 wire lead