Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
601
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Multimeter
Κωδικός ονόματος στοιχείου:
00794
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac and dc
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
3.187 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.125 inches
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
31 single indicator 3rd range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
31 single indicator 6th range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
31 single indicator 8th range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
50 single indicator 5th range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
50 single indicator 7th range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
50 single indicator 2nd range
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Dial w/pointer
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Bench
MRC:
The rated sensitivity of the item.ANTG
Sensitivity Rating:
50.0 microamperes
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black single indicator all ranges
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 4th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 7th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 8th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-3.0/+3.0 at full scale single indicator 1st range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-3.0/+3.0 at full scale single indicator 3rd range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-3.0/+3.0 at full scale single indicator 5th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-3.0/+3.0 at full scale single indicator 6th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-4.0/+4.0 at full scale single indicator 2nd range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0 to 2.0 at full scale single indicator 8th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0 to 2.0 at full scale single indicator 4th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0 to 2.0 at full scale single indicator 7th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-3.0 to 3.0 at full scale single indicator 1st range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-3.0 to 3.0 at full scale single indicator 3rd range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-3.0 to 3.0 at full scale single indicator 5th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-3.0 to 3.0 at full scale single indicator 6th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-4.0 to 4.0 at full scale single indicator 2nd range
MRC:
The hue or tint of the background.AQFY
Background Color:
White single indicator all ranges
MRC:
The hue or tint of the pointer.ASSS
Pointer Color:
Black single indicator all ranges
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Internal
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 2nd range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 3rd range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 5th range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 6th range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 7th range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 8th range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Nonlinear single indicator 1st range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Nonlinear single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1.0 milliamperes, ac single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1.0 milliamperes, dc single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1.0 volts, ac single indicator 5th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1.0 volts, dc single indicator 7th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1000.0 ohms single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+3.0 volts, ac single indicator 6th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+3.0 volts, dc single indicator 8th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-20.0/+2.0 decibels single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0 to 1.0 milliamperes, ac single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0 to 1.0 milliamperes, dc single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0 to 1.0 volts, ac single indicator 5th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0 to 1.0 volts, dc single indicator 7th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0 to 1000.0 ohms single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0 to 3.0 volts, ac single indicator 6th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0 to 3.0 volts, dc single indicator 8th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-20.0 to 2.0 decibels single indicator 1st range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Electrical overload protection and internal battery accommodation and portable and zero adjuster
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
2 probe, direct contact and 2 wire lead
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
1.5 dc
MRC:
Markings included on an item for the purpose of offering instructions or warnings or to indicate the purpose,function,or application of the item.excludes manufacturers part numbers,symbols,or the like.MARK
Special Markings:
Null guage: -; 0; +; band marked batt ok
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature:
Nonhardened
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Portable
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Test set, elect. Equip.