Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
670277-103
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Rotary Vacuum Pump Unit
Κωδικός ονόματος στοιχείου:
29904
MRC:
The power required to start and operate the item at the actual rated capacity,including all accessories.AAXW
Brake Horsepower Required:
0.333
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Any acceptable
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
2
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Threaded internal
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded internal
MRC:
Indicates the type of connection between the prime mover and the shaft.AAYX
Drive Connection Type:
Single strand v-belt
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The cooling medium used to maintain the required operating temperature of the item.ACZV
Cooling Medium:
Air
MRC:
The ultimate maximum vacuum,expressed in terms of absolute pressure,that may be produced by or applied to an item.ADLE
Vacuum Rating:
0.1 millitorr
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The specific gas with which the item is designed to be used.AENF
Specific Gas For Which Designed:
Air
MRC:
Indicates the type of pumping element included on the item.AENG
Pumping Element Type:
Rotary piston
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
1135.0
MRC:
The volume of air passed per unit of time through an item.AEQH
Air Displacement Rate:
3.0 cubic feet per minute in free air
MRC:
An indication of the system for which the item is designed.AERP
System Design:
Noncorrosive
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Heating equipment