Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
74a770620-9ata
Μονάδα μέτρησης:
No qup EA
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Sensitive Switch
Κωδικός ονόματος στοιχείου:
00399
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Bushing mounted
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
Actuator Style:
Round
MRC:
The length of a straight line which passes through the center of the actuator,and terminates at the circumference.AFUR
Actuator Diameter:
0.400 inches
Actuator Height:
0.660 inches
Actuator Free Position Height:
2.460 inches
MRC:
The length of a straight line which passes through the center of the housing, and terminates at the circumference.AFWB
Housing Diameter:
Between 0.625 inches and 0.675 inches
MRC:
A measurement of the longest dimension of the housing,in distinction from width.AFWD
Housing Length:
1.000 inches
Housing Bushing Length:
1.800 inches
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
2 pole, double throw, one position momentary single switch unit
MRC:
The amount to which the actuating force must be reduced to permit the switch to become unactuated.CRRM
Switch Release Force:
64.0 ounces
MRC:
The amount of force required to actuate the switch.CSJN
Switch Actuating Force:
144.0 ounces
MRC:
The movement of the switch actuator.CXQQ
Actuator Movement:
Between 0.050 pretravel inches and 0.500 overtravel inches and 0.030 differential inches
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
5.000 amperes resistive dc and 3.000 amperes inductive dc and 1.000 amperes lamp dc and 4.000 amperes motor dc and 1.000 amperes resistive ac and 1.000 amperes inductive ac and 1.000 amperes lamp ac and 1.000 amperes motor ac
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 cable w/connector