Osenses pressure differential froma pitot static and pressure tube to create a 0/5 vdc signal to indicate altitude and airspeed within 0.3 percent error; switch closes at 8300 feet or equivalent pressure differential
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Pressure Transmitter
Κωδικός ονόματος στοιχείου:
03375
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.500 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
An overall measurement of the smallest dimension of an item,in distinction from length or width.ADUM
Overall Thickness:
2.150 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Bellows
MRC:
The number of contacts which provide electrical connection.AFRA
Contact Quantity:
12
MRC:
Indicates the type of contact(s) included on the item.AKSF
Contact Type:
Pin
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
28.0 volts input
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
1
MRC:
The name of the government agency or commercial organization controlling the electrical connection.ASKY
Electrical Connection Controlling Agency:
Mil spec
MRC:
The identifying number assigned by the government agency or commercial organization controlling the electrical connection.ASKZ
Electrical Connection Identifying Number:
Ms24265r12d12p
MRC:
The number of mechanical connections provided.ASSB
Mechanical Connection Quantity:
2
MRC:
Designates the thread size,diameter,or the like,of the mechanical connection.ASSC
Mechanical Connection Size:
Number 4 and 6 an fitting
MRC:
Indicates the type of mechanical connection/s/ provided.ASSD
Mechanical Connection Type:
Flared tube pressure fitting
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange base
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+32.6 inches of mercury
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81755-c4204 manufacturers specification control