Αριθμός ανταλλακτικού:
83s
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Steam Trap
Κωδικός ονόματος στοιχείου:
04853
MRC:
The design of the body of the item.ALCS
Body Design:
Straight pattern
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel body err-100 err-100
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel, corrosion resisting working parts err-100 err-100
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel body
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Steel, corrosion resisting working parts
MRC:
Indicates the design type of the item.APGF
Design Type:
Pulsating continuous float
MRC:
The maximum steam pressure at which the item is designed to operate.AXSW
Maximum Steam Working Pressure:
150.0 pounds per square inch
MRC:
An indication of whether or not a strainer is included.BMBL
Strainer:
Not included
MRC:
The rated capacity of the item at maximum working pressure.BZSX
Rated Capacity At Maximum Working Pressure:
3870.000 pounds of water per hour
MRC:
A measurement of the area of the radiating surface on which the capacity of the item is based.BZSY
Radiating Surface Area On Which Capacity Is Based:
Any acceptable
MRC:
An indication of whether or not the inlet and/or outlet connection(s) is identical.BZTB
Inlet/outlet Connection Similarity:
Identical
MRC:
The value used to define the nominal diameter of the inlet and/or outlet connection pipe.BZTC
Inlet/outlet Connection Pipe Size:
1.000 inches
MRC:
An indication of whether or not the inlet and/or outlet connection is threaded.BZTH
Inlet/outlet Connection Thread Provision:
Unthreaded
MRC:
Indicates the location of the inlet in relation to the installed position of the item.BZTJ
Inlet Location In Relation To Installed Position:
Center side
MRC:
Indicates the location of the outlet in relation to the installed position of the item.BZTK
Outlet Location In Relation To Installed Position:
Center side
MRC:
An indication of whether or not a gage glass is included.BZTL
Gage Glass:
Not included
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Any acceptable