Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
8596842-007
Μονάδα μέτρησης:
No qup EA
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Quartz Crystal Unit
Κωδικός ονόματος στοιχείου:
00196
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 0.220 inches and 0.260 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.620 inches
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
Between 0.305 inches and 0.335 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.420 inches
MRC:
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.AEBT
Terminal Diameter:
Between 0.048 inches and 0.052 inches
MRC:
The mode of frequency at which the device is designed to operate.AEHC
Mode Of Oscillation:
Fundamental
MRC:
The condition existing when the frequency or vibration equals the natural frequency.AEHD
Circuit Resonance:
Antiresonance
MRC:
The amount of electrical capacitance under a load condition,required for normal operation in a circuit,expressed in picofarads.AEHE
Load Capacitance In Picofarads:
Between 32.5 and 33.5
MRC:
The total static capacitance of the item when measured across the terminals,expressed in picofarads.AEHF
Shunt Capacitance In Picofarads:
7.0
MRC:
The frequency at which the item is designed to operate under specified conditions.AEHG
Specified Frequency:
4.096 megahertz
MRC:
The permissible frequency deviation when operating at the reference temperature,expressed in percent.AEHK
Frequency Tolerance At Reference Tempurature In Percent:
-0.007/+0.007
MRC:
The allowable frequency deviation from the frequency measured at the reference temperature,expressed in percent.AEHL
Frequency Stability In Percent:
-0.001/+0.001
MRC:
The temperature at the midpoint of the controlled operating temperature range.AEHM
Controlled Reference Temp:
40.0 degrees celsius
MRC:
The temperature range over which units,designed for controlled temperature conditions,will oscillate.AEHN
Operable Tempurature Range:
+0.0/+80.0 degrees celsius
MRC:
The element,compound,or mixture of which the holder cover is fabricated.AEHS
Holder Cover Material:
Metal
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+115.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
6625-00-229-1049
Center To Center Distance Between Terminals:
0.190 mils and 0.210 centimeters
MRC:
The drive level at which the item is designed to operate.CQYL
Drive Level Rating:
Between 0.7 milliwatts and 1.0 milliwatts
MRC:
The permissible frequency deviation within the operating temperature range,expressed in percent.CRFX
Frequency Tolerance For Operating Tempurature In Percent:
-0.002/+0.002 and -0.005/+0.005
MRC:
The equivalent (effective) resistance for which the item is rated,expressed in ohms.CRMP
Equivalent Resistance Value In Ohms:
150.0
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Hat type, 3 wire leads