Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
9100-4722
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Power Transformer
Κωδικός ονόματος στοιχείου:
32496
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
3.125 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.500 inches single mounting facility single center group
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.218 inches single group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz single component or 60.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.750 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
3.125 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
3.025 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
6625-01-275-6268
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
2 primary single component and 3 secondary single component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
700.0 milliamperes ac single component 1st secondary400.0 milliamperes ac single component 2nd secondary6.6 amperes ac single component 3rd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
28.00 ac pounds per hour wet single component 1st secondary16.00 ac pounds per hour wet single component 2nd secondary5.90 ac pounds per hour wet single component 3rd secondary110.00 ac pounds per hour dry single component all primary and 120.00 ac pounds per hour with retaining chain single component all primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 wire lead and 2 connector, plug