Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
a10-1e2a-aam
Πληροφορίες ανταλλακτικού
With 10 ft type 316 stainless steel flexible cable stem, desplacement type liquid level control, explosion proof and waterproof switch housing and designed for 3/4 in. Conduit wiring
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Liquid Level Switch
Κωδικός ονόματος στοιχείου:
37187
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Any acceptable
MRC:
The length measured from the element to the extreme end of the power cable.ABJP
Power Cable Length:
Any acceptable
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Any acceptable
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Any acceptable
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
230.000 volts
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
Any acceptable
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Buoyancy
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Cable
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
6.5 amperes resistive load
MRC:
The number of floats provided.AWAE
Float Quantity:
2
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between 100.0 degrees fahrenheit and 400.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Thread
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Vertical
MRC:
The designation that identifies the schematic diagram of the contact arrangement.BJKD
Contact Arrangement:
Spst normally open
MRC:
An indication of whether or not a relay is included.BJKG
Relay:
Not included
MRC:
Indicates the type of liquid(s) for which the item is designed.BJKH
Liquid Type For Which Designed:
Diesel oil
MRC:
The distance of the effective travel of the float.BJKN
Float Effective Travel:
2.000 inches
MRC:
The mounting dimensions of the item.BJKP
Mounting Dimensions:
2-1/2 -8 npt thd connection
MRC:
A measurement of the longest dimension from the mounting surface to the end of the item,which is designed to be inserted into the tank.BJKQ
Tank Insertion Length:
Any acceptable
MRC:
The number of alternating current phases.FAAZ
Phase:
Single