Αριθμός ανταλλακτικού
Αποστρατιωτικοποίηση
Διάρκεια ζωής
UOM
NIIN
Αριθμός ανταλλακτικού:
a10982
NSN
Εθνικός αριθμός αποθέματος:
TXT
Περιγραφή:
Meter Movement Relay
Κωδικός ονόματος στοιχείου:
03884
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
4
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Wire loop
MRC:
The standard of valuation as represented by the inscription.ABWC
Scale Unit Of Measure Inscription:
Milliamperes
MRC:
Equal or unequal distances between graduations representing values of measurement on a scale.ABWF
Scale Linearity:
Nonlinear
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
20
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Three 0.112-40 unc-2a threaded studs spaced 120 degrees apart on 1.220 in. Radius
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 24.0 volts and 125.0 volts
MRC:
The minimum and maximum numeric values representing the measurement coverage of a scale.ANSZ
Scale Measurement Range:
+0.0/+40.0
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main contacts including the number of poles or forms.APDZ
Main Contact Arrangement:
1 pole, single throw, normally open, momentary action
MRC:
Indicates the type of current used by the main contact/s/.APEB
Main Contact Current Type:
Dc
MRC:
The current rating of the main contact/s/.APEC
Main Contact Current Rating:
50.0 milliamperes
MRC:
Indicates the type of current used in the meter movement.APGN
Meter Movement Current Type:
Dc
MRC:
An indication of the minimum and maximum amount of current used in the meter movement.APGR
Meter Movement Current Range:
+0.0/+40.0 milliamperes
MRC:
Indicates the type of mount utilized to support the meter.APMR
Meter Mounting Type:
Flush
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Not provided
MRC:
Indicates the type of lock in device provided.APNS
Lock In Device Type:
Electromagnetic
MRC:
The means by which the item is released.APNT
Release Method:
Electromagnetic
MRC:
The length of a straight line which passes through the center of the mounting flange,and terminates at the circumference.APTE
Mounting Flange Diameter:
2.800 inches
MRC:
The length of a straight line which passes through the center of the meter body and terminates at the circumference.APTF
Meter Body Diameter:
2.210 inches
MRC:
A measurement between the mounting flange and the face of the item, in distinction from height.APTN
Meter Depth To Mounting Flange:
1.470 inches